Download
PDMS-Series

PDMS Standard 2-Reagent Flow-Focusing Chips

Advantages of PDMS standard 2-reagent flow-focusing chips

Superior optical transparency

Excellent elastomeric properties

Non-toxicity

Biocompatibility

Good gas permeability, such as oxygen and carbon dioxide, can be advantageous in long-term cell cultures

Relatively low cost

FEATURES & BENEFITS

Features

PDMS standard 2-reagent flow-focusing chips

Droplet microfluidic is a field for turning a continuous fluid into microscale droplets based on the interfacial tension and flow shear between immiscible fluids. Compared with the cross-flowing geometry, the flow-focusing geometry is more stable, and has a wider range of microdroplet sizes. Therefore, it is currently the best choice for microdroplet generation.

FluidicLab provides PDMS standard 2-reagent flow-focusing chips. Each chip is covalently bonded from a perforated glass slide substrate and a PDMS chip with microscale channel, and the surface of channel is hydrophobic modified to ensure the stable generation of microdroplets. This type of chip is suitable for introducing 2 dispersed phases (usually aqueous solutions) and 1 continuous phase. Droplets are generated after the dispersed phases mixed together and sheared by the continuous phase. The two dispersed phases could be a cell suspension and barcode beads for single-cell sequencing libraries, or two immiscible aqueous phases for generating stable Janus microspheres.

Advantages of PDMS standard 2-reagent flow-focusing chips

1.Superior optical transparency
2.Excellent elastomeric properties
3.Non-toxicity
4.Biocompatibility
5.Good gas permeability, such as oxygen and carbon dioxide, can be advantageous in long-term cell cultures.
6.Relatively low cost

  • Encapsulation of single-cells microdroplets
  • Janus microspheres
  • 2-Reagent microdroplets/microspheres
SpecificationPDMS-SCE-30PDMS-SCE-50PDMS-SCE-100
MaterialPDMS & B270 glass
PDMS chip size62 mm × 19 mm × 2 mm
B270 glass size75 mm × 25 mm × 2 mm
FabricationSoft lithography, plasma treatment and covalent bonding
Max. Operating pressure4 bar
Channel modificationHydrophobic
Compatible holderStandard PDMS microfluidic chip holder (paired with three connector seal)
Droplet generation units1
On-B270 glass pore size1 mm
Channel width range30 μm ~ 250 μm30 μm ~ 250 μm80 μm ~ 350 μm
Flow focusing nozzle width30 μm30 μm60 μm
Microdroplet Sizes*25 μm ~ 35 μm40 μm ~ 60 μm85 μm ~ 140 μm
* The microdroplet sizes differ from one reagent to another, the data is for reference only.
ChipMicrodroplet typeContinuous phaseDispersed phase
Hydrophobic chipWater-in-Oil2% Drop-Surf Droplet Generation OilWater

NEED HELP OR TECHNICAL INFORMATION?

GET IN TOUCH

Talk to our experts
Contact Form

PRODUCTS

Fluid Control Systems
Droplet Microfluidic Systems
LNP Synthesis System
Measurement & Detection
Microfluidic Chips
Microfluidic Reagents

APPLICATION

Hydrogel Microspheres
Nanoparticles Packs
Dissolvable gel beads

INDUSTRY

OEM Products

CONTACT

  • 315, Building 1, No. 8 Memorial Road, Yangpu District, Shanghai, China
  • +86 021-65103566